Posted by cato
![]()
on 8/20/2007, 11:33 am, in reply to "MIG Welding Back Burn Problem"
80.202.186.102
The electronics controlling the feed can be adjusted to allow higher feed at startup and delay on wire-feed-stop at the end. There should be an adjustable rotation-switch on the control board, probably "sealed" with varnish.